ACLSPro.com ACLS 2005 Pulseless Electrical Activity (PEA) Algorithm

The following directs AHA accepted actions as part of the Secondary ABCDs for pulselessness with an organized cardiac rhythm. Provide 2 minute cycles of CPR-rhythm/pulse checks and think:

P E A

Letter Intervention
P Problem search (see Differential Diagnosis Table). Treat accordingly. Continue this algorithm if indicated.
E Epinephrine 1 mg IV/IO q3-5 min. Or vasopressin 40 U IV/IO, once, in place of the 1st or 2nd dose of epi.
A Atropine, with a slow heart rate, 1 mg IV/IO q3-5 min. (3mg max.)
 